01
01
KGR2

KGR2 Adjustable Thermal Overload Relay

Share
KGR2 thermal overload relay covers adjustable current settings from 0.1A to 93A for AC motor overload protection. Send your current range for a CANGO quote.
Timer Relay / Industrial Control Relay
KGR2 Adjustable Thermal Overload Relay

The KGR2 adjustable thermal overload relay protects motor circuits against sustained overloads. Its current-setting bands allow the protection setting to be matched to the motor, supporting starter assemblies and machinery control panels.

Model
KGR2
Product Type
Adjustable motor thermal-overload protection relay
Application Focus
AC motor overload and auxiliary control-circuit protection
KGR2 adjustable thermal overload relay for AC motor protection

Buyer Overview

KANGGE ELECTRIC supplies the KGR2 series for importers, distributors, panel builders, machinery manufacturers, contractors and OEM electrical-equipment buyers.

The KGR2 adjustable thermal overload relay protects motor circuits against sustained overloads. Its current-setting bands allow the protection setting to be matched to the motor, supporting starter assemblies and machinery control panels.

KGR2 Quick Selection: Confirm the exact model, supply or coil voltage, timing or current setting, contact arrangement, mounting method, application and quantity before quotation.

Product Advantages

  • •Select the motor overload protection relay by the motor current and the corresponding thermal-component setting band.
  • •Thermal relay current adjustment is specified by individual model; the KGR2-1301 row, for example, lists a 0.10-0.16A setting range.
  • •The KGR2-13 overload relay group has a listed rated working current of 25A and several thermal-component options.
  • •The KGR2-3365 thermal relay row lists an 80.0-93.0A adjustment range for the corresponding higher-current selection.

Technical Specifications

TypeRated Working
Current of The Thermal Relay
Thermal Component
Rated Current(A)Rated or Scale of
Rated Current(A)
KGR2-1325KGR2-13010.160.10-0.16
KGR2-13020.250.16-0.25
KGR2-13030.400.25-0.40
KGR2-13040.630.41-0.63
KGR2-13051.00.63-1.0
KGR2-13061.61.0-1.6
KGR2-13X62.01.25-2.0
KGR2-13072.51.6-2.5
KGR2-13084.02.5-4.0
KGR2-13106.04.0-6.0
KGR2-13128.05.5-8.0
KGR2-131410.07.0-10.0
KGR2-131613.09.0-13.0
KGR2-132118.012.0-18.0
KGR2-132225.017.0-25.0
KGR2-2336VR2-23533223.0-32.0
KGR2-23553628.0-36.0
CER2-3393KGR2-33533223.0-32.0
CER2-33554030.0-40.0
KGR2-33575037.0-50.0
KGR2-33596548.0-65.0
KGR2-33617055.0-70.0
KGR2-33638063.0-80.0
KGR2-33659380.0-93.0
Use GroupACLLDCLL
Rated Working Voltage(V)220380500220110
Rated Working Current(A)432010.22
Appointed Thermal Current(A)5

Dimensions and Original Product References

KGR2 thermal overload relay original technical image

Applications

  • •AC motor overload-protection circuits
  • •Thermal relay for AC contactor and starter assemblies
  • •Pump, fan and compressor control panels
  • •Machine-building electrical systems
  • •OEM motor-control equipment

Model Selection Guide

  • •Match the motor full-load current to the adjustable current scale in the first table.
  • •Confirm the required 25A, 36A or 93A frame group.
  • •Use the listed thermal-component code for ordering.
  • •Review the auxiliary-circuit use group, voltage and current table.
  • •Send motor current, contactor model, control voltage and quantity with the inquiry.

KGR2 FAQ

What current-setting range is covered by the KGR2 table?
The retained model table covers adjustable settings from 0.10A to 93A across several frame groups.
Which frame current groups are listed for KGR2?
The source content lists 25A, 36A and 93A rated working-current groups.
Does the KGR2 relay include auxiliary contacts?
The original text states one normally open and one normally closed electrically insulated auxiliary contact.
What data are required for KGR2 selection?
For a motor phase failure overload relay supplier inquiry, provide motor full-load current, contactor or starter reference, control-circuit requirements and order quantity.

Send Inquiry

For a KGR2 quotation, send the selected model, supply or coil voltage, timing or current requirement, contact configuration, mounting method, quantity and destination market. Our team can review the retained technical table with your project requirements.

Contact KANGGE ELECTRIC

Browse more products in the Timer Relay, SSR and Thyristor Control Components category.

RELATED NEWS

News

News

News

CONTACT US

No.268,Punan Fifth Road,Yueqing Economic Development Zone,Yueqing,Zhejiang,China. 325604

+86-0577-57112069

+86-13588992688

peggy@cncango.com

Package Details

Products usually are typically packed in a plastic bag, then in a separate cardboard box, and several boxes are then packed into a corrugated carton. For loose cargo, we will palletize it to protect the goods from deformation during transport. We also accept customized package.

What Is Film Faced Plywood ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

How Is It Made ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

What Is It Used For ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

Performance

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

Provides A Solution To Your Problem

If You Have Any Comments Or Suggestions Or Our Quality Or Service Can Not Satisfy You, Please Call Our Customer Service Center, Register Through Our Website, Our Customer Service Staff Will Be The First Time To Understand The Situation, Timely Contact With You.