01
02
KGR

KGR Thermal Relay

Share
KGR Thermal Overload Relay for industrial control panels. Contact CANGO for confirmed specifications, model selection and quotation.
Timer Relay / Industrial Control Relay
KGR Thermal Relay

The KGR thermal overload relay provides adjustable overload protection for motor starter circuits. The KGR-13, KGR-23 and KGR-33 groups cover different current-setting bands for matching the relay to the motor load.

Model
KGR
Product Type
Thermal Overload Relay
Application Focus
Motor overload protection and low-voltage control panels
KGR Thermal Overload Relay product image

Buyer Overview

KANGGE ELECTRIC supplies the KGR series for importers, distributors, panel builders, machinery manufacturers, contractors and OEM electrical-equipment buyers.

The KGR thermal overload relay provides adjustable overload protection for motor starter circuits. The KGR-13, KGR-23 and KGR-33 groups cover different current-setting bands for matching the relay to the motor load.

KGR Quick Selection: Confirm the exact model, supply or coil voltage, timing or current setting, contact arrangement, mounting method, application and quantity before quotation.

Product Advantages

  • •Choose the adjustable overload current setting by the thermal-component code and the motor's required current range.
  • •The KGR-13 thermal relay group lists a rated working current of 25A with multiple thermal-component bands, including 0.10-0.16A and 16.0-24.0A.
  • •The KGR-23 overload relay group lists 23.0-32.0A and 30.0-38.0A setting options under a 38A rated-working-current heading.
  • •KGR-33 motor overload protection selections include component bands from 17.0-25.0A up to 110.0-140.0A.

Technical Specifications

TypeRated Working
Current of The Thermal Relay
Thermal Component
Rated Current
(A)
Rated or
Scale of Rated
Current(A)
KGR-1325KGR13010.160.10-0.16
13020.250.16-0.25
13030.400.25-0.40
13040.630.40-0.63
13051.00.63-1.0
13061.61.0-1.6
13072.51.6-2.5
13084.02.5-4.0
13106.04.0-6.0
13128.05.5-8.0
131410.07.0-10.0
131613.09.0-13.0
132118.012.0-18.0
132225.016.0-24.0
KGR-2338KGR23323223.0-32.0
23353830.0-38.0
KGR-33140KGR33222517.0-25.0
33533223.0-32.0
33554030.0-40.0
33575037.0-50.0
33596548.0-65.0
33617055.0-70.0
33638063.0-80.0
336510480.0-104.0
336712095.0-120.0
3369140110.0-140.0
KGR-34140KGR436510480.0-104.0
436712095.0-120.0
4369104110.0-140.0

Applications

  • •Motor overload protection and low-voltage control panels
  • •Low-voltage electrical control and automation projects
  • •OEM equipment and control-panel assembly
  • •Replacement and maintenance selection based on the exact model
  • •B2B supply for importers, distributors, contractors and project buyers

Model Selection Guide

  • •Confirm the complete model and required function before quotation.
  • •Check the original technical table for available operating parameters and configuration options.
  • •Verify the control voltage or supply voltage, contact arrangement and wiring method when applicable.
  • •Confirm the mounting method, application conditions and required accessories.
  • •Send the selected model, project requirements, quantity and destination market for technical review.

KGR FAQ

What is the KGR product used for?
It is intended for motor overload protection and low-voltage control panels. Confirm suitability against the original technical data and project circuit.
How should buyers select the KGR model?
Compare the confirmed source table with the required voltage, function, contact or output configuration, mounting method and application.
Can CANGO support B2B and OEM requirements?
Buyers can send the exact model, technical requirements, order quantity, branding or packing request and destination market for review.
What is needed for a KGR quotation?
For a KGR quotation, provide the required parameters, wiring or mounting details, quantity and destination market.

Send Inquiry

For a KGR quotation, send the selected model, supply or coil voltage, timing or current requirement, contact configuration, mounting method, quantity and destination market. Our team can review the retained technical table with your project requirements.

Contact KANGGE ELECTRIC

Browse more products in the Timer Relay, SSR and Thyristor Control Components category.

RELATED NEWS

News

News

News

CONTACT US

No.268,Punan Fifth Road,Yueqing Economic Development Zone,Yueqing,Zhejiang,China. 325604

+86-0577-57112069

+86-13588992688

peggy@cncango.com

Package Details

Products usually are typically packed in a plastic bag, then in a separate cardboard box, and several boxes are then packed into a corrugated carton. For loose cargo, we will palletize it to protect the goods from deformation during transport. We also accept customized package.

What Is Film Faced Plywood ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

How Is It Made ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

What Is It Used For ?

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

Performance

Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.

Provides A Solution To Your Problem

If You Have Any Comments Or Suggestions Or Our Quality Or Service Can Not Satisfy You, Please Call Our Customer Service Center, Register Through Our Website, Our Customer Service Staff Will Be The First Time To Understand The Situation, Timely Contact With You.