CJX3-G AC CONTACTOR
CJX3-G GMC AC Contactor
CJX3-G GMC AC Contactor is intended for industrial motor-control and remote circuit-switching requirements. Its original four technical tables and uploaded product drawings are retained for model comparison, including operational current, motor power, auxiliary contact, insulation voltage, and coil selections.
Buyer Overview
KANGGE ELECTRIC supplies CJX3-G GMC AC Contactor for importers, distributors, panel builders, machinery manufacturers, contractors, and industrial project buyers.
CJX3-G GMC AC Contactor is intended for industrial motor-control and remote circuit-switching requirements. Its original four technical tables and uploaded product drawings are retained for model comparison, including operational current, motor power, auxiliary contact, insulation voltage, and coil selections.
Key Features
- •The original tables cover CJX3-G09(Z) through CJX3-G800 model groups.
- •AC-3 operational current is listed across multiple operating voltages.
- •Controlled three-phase cage-motor power is retained for model comparison.
- •Auxiliary-contact configurations are shown in the source data.
- •AC and DC coil-voltage selections remain visible for control-circuit matching.
Technical Specifications
The following tables are retained from the current product page. Their technical values, model labels, row spans, and column spans are preserved; only the visual styling is standardized for clearer blue-and-white reading.
Original Technical Table 1
Items | Model | CJX3-G09(Z) | CJX3-G12(Z) | CJX3-G18(Z) | CJX3-G22(Z) | CJX3-G32(Z) | |
Pole | 3 | 3 | 3 | 3 | 3 | ||
Auxiliary Contact | 1 NO+ 1 NC | 1 NO+ 1 NC | 1 NO+ 1 NC | 1 NO+ 1 NC | 0NO+ 0 NC | ||
Rated conventional heating current (A) AC-1 | 20 | 20 | 30 | 40 | 50 | ||
Rated Operational Current(A) | AC-3 | 220/240V | 11 | 13 | 18 | 22 | 32 |
| 380/415V | 9 | 12 | 18 | 22 | 32 | ||
500/500V | 7 | 12 | 13 | 22 | 28 | ||
| 690V | 5 | 9 | 9 | 18 | 20 | ||
Rated insulation Voltage(V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-Phase Cage motor(AC-3) | kW | 220/240V | 2.5 | 3.5 | 4.5 | 5.5 | 7.5 |
| 380/415V | 4 | 5.5 | 7.5 | 11 | 15 | ||
| 500/500V | 4 | 7.5 | 7.5 | 15 | 18.5 | ||
| 690V | 4 | 7.5 | 7.5 | 15 | 18.5 | ||
AC Coil (V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC Coil (V) | 24,36,48,110,220 | ||||||
Original Technical Table 2
Items | Model | CJX3-G40(Z) | CJX3-G50(Z) | CJX3-G65(Z) | CJX3-G75(Z) | CJX3-G85(Z) | |
Pole | 3 | 3 | 3 | 3 | 3 | ||
Auxiliary Contact | 0 NO+ 0 NC | 0 NO+ 0 NC | 0NO+ 0 NC | 0 NO+ 0 NC | 0 NO+ 0 NC | ||
Rated conventional heating current (A) AC-1 | 60 | 80 | 100 | 110 | 125 | ||
Rated Operational Current(A) | AC-3 | 220/240V | 40 | 50 | 65 | 75 | 85 |
| 380/415V | 40 | 50 | 65 | 75 | 85 | ||
500/500V | 32 | 43 | 60 | 64 | 75 | ||
| 690V | 23 | 28 | 35 | 42 | 45 | ||
Rated insulation Voltage(V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-Phase Cage motor(AC-3) | AC-3 | 220/240V | 11 | 15 | 18l.5 | 22 | 25 |
| 380/415V | 18.5 | 22 | 30 | 37 | 45 | ||
| 500/500V | 22 | 30 | 33 | 37 | 45 | ||
| 690V | 22 | 30 | 33 | 37 | 45 | ||
AC Coil (V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC Coil (V) | 24,36,48,110,220 | ||||||
Original Technical Table 3
Items | Model | CJX3-G100 | CJX3-G125 | CJX3-G150 | CJX3-G180 | CJX3-G220 | |
Pole | 3 | 3 | 3 | 3 | 3 | ||
Auxiliary Contact | 1 NO+ 1 NC | 1 NO+ 1 NC | 1 NO+ 1 NC | 1 NO+ 1 NC | 0 NO+ 0 NC | ||
Rated conventional heating current (A) AC-1 | 160 | 160 | 210 | 230 | 275 | ||
Rated Operational Current(A) | AC-3 | 220/240V | 100 | 125 | 150 | 180 | 250 |
| 380/415V | 100 | 125 | 150 | 180 | 250 | ||
500/500V | 85 | 90 | 140 | 180 | 200 | ||
| 690V | 65 | 70 | 100 | 120 | 150 | ||
Rated insulation Voltage(V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-Phase Cage motor(AC-3) | kW | 220/240V | 30 | 37 | 45 | 55 | 75 |
| 380/415V | 55 | 60 | 75 | 90 | 132 | ||
| 500/500V | 55 | 60 | 90 | 110 | 132 | ||
| 690V | 55 | 60 | 901 | 110 | 132 | ||
AC Coil (V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC Coil (V) | 24,36,48,110,220 | ||||||
Original Technical Table 4
Items | Model | CJX3-G300 | CJX3-G400 | CJX3-G600 | CJX3-G800 | |
Pole | 3 | 3 | 3 | 3 | ||
Auxiliary Contact | 0 NO+ 0 NC | 0 NO+ 0 NC | 0 NO+ 0 NC | 0 NO+ 0 NC | ||
Rated conventional heating current (A) AC-1 | 350 | 450 | 660 | 850 | ||
Rated Operational Current(A) | AC-3 | 220/240V | 300 | 400 | 600 | 800 |
| 380/415V | 300 | 400 | 600 | 800 | ||
500/500V | 250 | 350 | 500 | 720 | ||
| 690V | 220 | 300 | 420 | 630 | ||
Rated insulation Voltage(V AC) | 690 | 690 | 690 | 690 | ||
Power of controlled 3-Phase Cage motor(AC-3) | kW | 220/240V | 90 | 125 | 190 | 220 |
| 380/415V | 160 | 220 | 330 | 440 | ||
| 500/500V | 160 | 225 | 330 | 550 | ||
| 690V | 200 | 250 | 330 | 500 | ||
AC Coil (V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | |||||
DC Coil (V) | 24,36,48,110,220 | |||||
Dimensions and Original Drawings
The following uploaded images are retained from the current product page for model identification, technical reference, and dimension checking. Confirm the selected model against the latest drawing before panel layout or installation.











Applications
- •Industrial motor starting and stopping circuits
- •Machine-control panels and automation equipment
- •Remote circuit switching in low-voltage systems
- •OEM motor starters and electrical control assemblies
- •Wholesale replacement and project-sourcing programs
Model Selection and Inquiry Notes
- •Identify the correct CJX3-G model and required current range.
- •Match the AC-3 duty and operating voltage to the motor application.
- •Check motor-power data in the retained source table.
- •Confirm the auxiliary-contact arrangement and coil voltage.
- •Review the original drawings and provide quantity details before quotation.
Related Search Terms
- CJX3-G GMC type AC contactor - use this phrase when the model and application match the inquiry.
- 9A to 800A motor starter contactor - use this phrase when the model and application match the inquiry.
- GMC frame magnetic contactor wholesale - use this phrase when the model and application match the inquiry.
- CJX3-G AC-3 AC-4 contactor - use this phrase when the model and application match the inquiry.
- industrial contactor coil voltage selection - use this phrase when the model and application match the inquiry.
CJX3-G GMC FAQ
What model range is shown for the CJX3-G GMC AC Contactor?
What should buyers confirm for CJX3-G coil selection?
Is CJX3-G intended for motor-control applications?
Are the original technical drawings included?
Send Inquiry
For a CJX3-G GMC quotation, send the selected model, operating voltage, motor power, utilization duty, coil voltage, pole or contact requirement, quantity, destination market, and required delivery schedule.
Contact KANGGE ELECTRICView More ContactorsRELATED NEWS
News
News
News
CONTACT US
No.268,Punan Fifth Road,Yueqing Economic Development Zone,Yueqing,Zhejiang,China. 325604
+86-0577-57112069
+86-13588992688
peggy@cncango.com
What Is Film Faced Plywood ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
How Is It Made ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
What Is It Used For ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
Performance
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
Provides A Solution To Your Problem
If You Have Any Comments Or Suggestions Or Our Quality Or Service Can Not Satisfy You, Please Call Our Customer Service Center, Register Through Our Website, Our Customer Service Staff Will Be The First Time To Understand The Situation, Timely Contact With You.