CJX2-F AC CONTACTOR
CJX2-F High Current AC Contactor
CJX2-F AC Contactor is a high-current contactor series for industrial switching and motor-control projects. The original website tables are preserved to support comparison of models, AC-3 and AC-4 operational current, motor power, insulation voltage, pole options, and AC coil voltage.
Buyer Overview
KANGGE ELECTRIC supplies CJX2-F AC Contactor for importers, distributors, panel builders, machinery manufacturers, contractors, and industrial project buyers.
CJX2-F AC Contactor is a high-current contactor series for industrial switching and motor-control projects. The original website tables are preserved to support comparison of models, AC-3 and AC-4 operational current, motor power, insulation voltage, pole options, and AC coil voltage.
Key Features
- •The original table retains model selections from CJX2-F115 through the high-current series.
- •AC-3 and AC-4 operational-current values are provided for model comparison.
- •Controlled three-phase motor power is listed at the source-page voltage levels.
- •Three-pole and four-pole configurations are identified in the original table.
- •AC coil-voltage choices are preserved for quotation and control-circuit matching.
Technical Specifications
The following tables are retained from the current product page. Their technical values, model labels, row spans, and column spans are preserved; only the visual styling is standardized for clearer blue-and-white reading.
Original Technical Table 1
| ltems | Model | CJX2-F115 | CJX2-F150 | CJX2-F185 | CJX2-F225 | CJX2-F265 | CJX2-F330 | |
| Pole | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | ||
| Rated conventional heating current(A) AC-1 | 200 | 200 | 275 | 280 | 350 | 360 | ||
| Rated operational current (A) | 380/400V | AC-3 AC-4 | 115 | 150 | 185 | 225 | 265 | 330 |
| 50 | 65 | 75 | 85 | 100 | 124 | |||
| 660/690V | AC-3 AC-4 | 70 | 90 | 108 | 115 | 170 | 190 | |
| 25 | 32 | 38 | 40 | 47 | 60 | |||
| Rated insulation voltage (V AC) | 690 | 690 | 690 | 690 | 690 | 690 | ||
| Power of controlled 3-phase cage motor (AC-3) | kW | 380/415VAC 660/690VAC | 55 | 75 | 90 | 110 | 132 | 160 |
| 80 | 100 | 110 | 140 | 160 | 220 | |||
| AC coil (V) | 110,127,220,240,380,415,440,480,500,600 | |||||||
Original Technical Table 2
| ltems | Model | CJX2-F115 | CJX2-F150 | CJX2-F185 | CJX2-F225 | CJX2-F265 | CJX2-F330 | |
| Pole | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | ||
| Rated conventional heating current(A) AC-1 | 430 | 580 | 850 | 850 | 1200 | 1200 | ||
| Rated operational current (A) | 380/400V | AC-3 AC-4 | 400 | 500 | 630 | 800 | 780 | 1000 |
| 150 | 185 | 188 | 195 | 240 | - | |||
| 660/690V | AC-3 AC-4 | 235 | 290 | 360 | 486 | - | - | |
| 72 | 85 | 170 | - | - | - | |||
| Rated insulation voltage (V AC) | 690 | 690 | 690 | 690 | 690 | 690 | ||
| Power of controlled 3-phase cage motor (AC-3) | kW | 380/415VAC 660/690VAC | 200 | 250 | 335 | 400 | 400 | 500 |
| 280 | 330 | 450 | 475 | 475 | 670 | |||
| AC coil (V) | 110,127,220,240,380,415,440,480,500,600 | |||||||
Dimensions and Original Drawings
The following uploaded images are retained from the current product page for model identification, technical reference, and dimension checking. Confirm the selected model against the latest drawing before panel layout or installation.

Applications
- •Heavy-duty industrial motor switching
- •Large machinery and production-line control panels
- •Power distribution control circuits
- •OEM switchboards and motor-control centers
- •Distributor and project-based high-current contactor sourcing
Model Selection and Inquiry Notes
- •Select the model according to the required operational current and utilization duty.
- •Check the controlled motor power against the operating voltage in the source table.
- •Confirm whether a three-pole or four-pole configuration is required.
- •Specify the control-circuit coil voltage.
- •Provide the required quantity and panel application for quotation review.
Related Search Terms
- CJX2-F high current AC contactor - use this phrase when the model and application match the inquiry.
- 115A to 1000A industrial contactor - use this phrase when the model and application match the inquiry.
- heavy duty motor switching contactor - use this phrase when the model and application match the inquiry.
- CJX2-F contactor for control panels - use this phrase when the model and application match the inquiry.
- high amperage contactor export supplier - use this phrase when the model and application match the inquiry.
CJX2-F FAQ
What makes the CJX2-F series suitable for high-current projects?
Which data should be confirmed before ordering CJX2-F?
Can CJX2-F be used in industrial control panels?
Are the original CJX2-F tables retained?
Send Inquiry
For a CJX2-F quotation, send the selected model, operating voltage, motor power, utilization duty, coil voltage, pole or contact requirement, quantity, destination market, and required delivery schedule.
Contact KANGGE ELECTRICView More ContactorsRELATED NEWS
News
News
News
CONTACT US
No.268,Punan Fifth Road,Yueqing Economic Development Zone,Yueqing,Zhejiang,China. 325604
+86-0577-57112069
+86-13588992688
peggy@cncango.com
What Is Film Faced Plywood ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
How Is It Made ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
What Is It Used For ?
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
Performance
Film Faced Plywood Is A Type Of Plywood That Has Thin Film Coating On The Surface, Providing High Water Resistance, Stain Resistance, And Durability. It Is Widely Used N The Construction Industry.
Provides A Solution To Your Problem
If You Have Any Comments Or Suggestions Or Our Quality Or Service Can Not Satisfy You, Please Call Our Customer Service Center, Register Through Our Website, Our Customer Service Staff Will Be The First Time To Understand The Situation, Timely Contact With You.